1、英文原文 Double Loop DC Speed Control System Description.system analysis and synthesis1Analysis (1)In the speed and current dual closed-loop speed control system, in order to change the motor speed, what parameters should be regulating? Change speed regulator Kn magnification work? Power electronic conv
2、erter to change the magnification factor Ks work? Change the speed of the feedback coefficient of work? To change the motors stall current system should adjust the parameters of what?A: To change the motor speed, change speed regulator Kn magnification and power electronic converters will not work m
3、agnification factor Ks, stable when n = Un = Un *, so the only change in the value of a given coefficient of Un * and feedback before. To change the motors stall current, only need to change the same value given Uim * and feedback coefficient, because the stability, Uim * = Idm, can be drawn from th
4、e type (2) Speed, the current double closed-loop speed control system when the steady-state operation, the two regulator input voltage and output voltage deviation is the number? A: The speed and current dual closed-loop speed control system when the steady-state operation, the two regulators are th
5、e input bias voltage is zero, by the formula n = Un = Un *, n = n; Uim * = Idm, Idm = Idl. (3) In the speed and current dual closed-loop speed control system, the two regulators are PI regulator. When the system is running with rated load, the speed feedback line suddenly disconnected, the system re
6、-enter the steady-state, the current regulator is the input bias voltage to zero? Why? A: When the system is running with rated load, the speed feedback line suddenly disconnected, then Un = 0, = Un *- Un = Un *, so that Ui to reach Uim, 0, rate of increase in n, when the system after re-entering th
7、e steady-state , that is, Id = Idl, then, = Uim *- Idl 0, are no longer changes, changes in rotational speed n is no longer, but at this time than the rotational speed n at the time of the feedback line speed to break big. (4) Why is the speed with integral control system is not static poor? A: Spee
8、d regulator integral system, to achieve non-static error is due to the characteristics of integral control regulator, that is, the accumulation of points and the role of memory. (5) Double-loop speed control system (PI), load changes, Idl Idm, asked bicyclol speed control system ASR and ACR how-cond