1、外文文献:Basic Principles of Lightning ProtectionA lightning conductor is a device invented by Benjamin Franklin to protect buildings from lightning strikes. It provides a low-resistance path for the lightning current to flow to the ground, preventing any damage that would have resulted if the lightning
2、 current had passed through the building to the ground. Let us now consider how a lightning conductor acts during a lightning strike. Recent research has shown that when allowed to compete with each other, lightning rods with moderately blunt tips perform better than rods with sharp tips.The electro
3、-geometrical method (EGM) is a simple procedure used by lightning protection engineers to evaluate the attractive range of a lightning conductor 1. Let us first examine the basic assumptions of this method.Two basic assumptions are made in EGM. The first assumption is that inevaluating a lightning a
4、ttachment to structures one can neglect the effect of connecting leaders. Since connecting leaders are an integral part of lightning attachment, this assumption is not justified. However, the length of the connecting leader depends on the height of the structure. It increases with increasing structu
5、re height. This assumption is therefore justified only in the case of short structures where the influence of the connecting leader on the lightning attachment is slight. With increasing structure height the effect of connecting leaders on lightning attachment increases, and one would expect the res
6、ults obtained from EGM to deviate from reality. The second assumption is that a stepped leader is attracted to a grounded structure when it reaches a critical distance from the grounded structure. This critical distance is called the striking distance. It can be described as the distance of the fiel
7、d of vision of the stepped leader. If the distance from a grounded structure to the stepped leader is larger than the striking distance, then the stepped leader is not aware of the grounded structure. The reason for this assumption in EGM is as follows. As the distance between a grounded structure a
8、nd the tip of the stepped leader decreases, the average electric field in the space between the grounded structure and the tip of the stepped leader increases. When this average electric field reaches a critical value, the positive streamers (in the case of a negative stepped leader, of course) gene