欢迎来到图海文库! | 帮助中心 分享价值,成长自我!
图海文库
全部分类
  • 机械模具>
  • 机电控制>
  • 工艺夹具>
  • 车辆工程>
  • 化工环保>
  • 土木建筑>
  • 采矿通风>
  • CAD图纸>
  • 三维模型>
  • 数控编程>
  • 文档资料>
  • ImageVerifierCode 换一换
    首页 图海文库 > 资源分类 > DOC文档下载
    分享到微信 分享到微博 分享到QQ空间

    外文翻译 - 火灾报警控制面板.doc

    • 资源ID:20707       资源大小:69.74KB        全文页数:15页
    • 资源格式: DOC        下载积分:10金币
    微信登录下载
    验证码下载 游客一键下载
    账号登录下载
    三方登录下载: QQ登录
    二维码
    微信扫一扫登录
    下载资源需要10金币
    邮箱地址:
    验证码: 获取验证码
    温馨提示:
    支付成功后,系统会自动生成账号(用户名为邮箱地址,密码是验证码),方便下次登录下载和查询订单;
    支付方式: 支付宝    微信支付   
    验证码:   换一换

     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    外文翻译 - 火灾报警控制面板.doc

    1、外文文献及译文文献、资料题目:Fire alarm control panel文献、资料来源:http:/en.wikipedia.org文献、资料发表(出版)日期: 院 (部): 专 业: 班 级: 姓 名: 学 号: 指导教师: 翻译日期: 外文文献:Fire alarm control panel A Fire Alarm Control Panel (FACP), or Fire Alarm Control Unit (FACU), is the controlling component of a Fire alarm System. The panel receives infor

    2、mation from environmental sensors designed to detect changes associated with fire, monitors their operational integrity and provides for automatic control of equipment, and transmission of information necessary to prepare the facility for fire based on a predetermined sequence. The panel may also su

    3、pply electrical energy to operate any associated sensor, control, transmitter, or relay. There are four basic types of panels: coded panels, conventional panels, addressable panels, and multiplex systems.Contents1 Coded Fire Alarm Control Panels2 Conventional Fire Alarm Control Panels3 Multiplex sys

    4、tems4 Releasing panels5 Addressable Fire Alarm Control Panels 5.1 Signaling Line Circuits 5.2 Mapping 5.2.1 Zones 5.2.2 Groups 5.2.3 Boolean logic6 Networking7 Monitoring8 System functions 8.1 System reset 8.2 Acknowledge 8.3 Drill 8.4 Walk test 8.5 Signal silence 8.6 Lamp test 9 AC power10 DC power

    5、1 Coded Fire Alarm Control PanelsCoded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel ( i.e. An alar

    6、m in zone 1 would sound code 1-2-4 through the bells or horns in the building, while zone 2 would sound 1-2-5), which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset (similar to a coded(pull station) or run continuou

    7、sly until the panel itself was reset. Large panels could take up an entire wall in a mechanical room, with dozens of code wheels. Lists of codes had to be maintained, sometimes with copies posted above pull stations (this setup is commonly seen in older wings of hospitals). Smaller panels could be s

    8、et up in one of two ways. Most of the time, the panel would only have one zone, and therefore, only one code. Common one-zone codes were 4-4-0 and 17-0-0 (which is similar to the 120 bpm March Time setting used on later panels, which has in turn been replaced with a interrupted four count uniform te

    9、mporal code 3 pattern used since 1996). Alternatively, the panel could be made with no code wheels, using only what was called the gong relay. Normally, this would be used in a system with coded pull stations to retransmit the coding strikes from the pulls. However, it could also be used as its own

    10、zone, with the connected horns or bells sounding continuously instead of in a particular code. These panels are not common today, but can sometimes be found in older buildings such as those on college campuses or hospitals.2 Conventional Fire Alarm Control PanelsConventional panels have been around

    11、ever since electronics became small enough to make them viable. conventional panels are used less frequently in large buildings than in the past, but are not uncommon on smaller projects such as small schools, stores, restaurants, and apartments.A conventional Fire Alarm Control Panel employs one or

    12、 more circuits, connected to sensors initiating devices wired in parallel. These sensors are devised to dramatically decrease the circuit resistance when the environmental influence on any sensor exceeds a predetermined threshold. In a conventional fire alarm system, the information density is limit

    13、ed to the number of such circuits used.To facilitate location and control of fire within a building, the structure is subdivided into definite areas or zones. Floors of a multistory building are one type of zone boundary.An Initiating Device Circuit connected to multiple devices within the same zone

    14、 of protection, effectively provides 2 bits of information about the zone corollary to the state of the circuit; normal, or off normal and alarm or quiescent. The state of each Initiating Device Circuit within a zone displays at the Fire Alarm Control Panel using visible indications called annunciat

    15、orsThese Annunciators may employ a graphical representation of the Zone boundaries on a floor plan (Zone map) using textual descriptions, illuminated icons, illuminated sections, or illuminated points on the map corresponding to Initiating Circuits connected to the Fire Alarm Control Panel.For this

    16、reason, slang often inaccurately refers to initiating circuits of a Fire Alarm Control Panel as Zones.Larger systems and increasing demand for finer diagnostic detail beyond broad area location and control functions expanded the control by Zone strategy of conventional systems by providing multiple initiating circuits within a c


    注意事项

    本文(外文翻译 - 火灾报警控制面板.doc)为本站会员主动上传,图海文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知图海文库(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    网站客服QQ:2356858848

      客服联系电话:18503783681

    copyright@ 2008-2022 thwenku.com网站版权所有

    ICP备案:豫ICP备2022023751号-1